Description
The InFiltra Filtered Supply Unit has been designed to provide
filtered outside air to a range of applications. Can be wired in
high, medium and low speed and includes a high performance
centrifugal impeller.
Features
- Durable zinc coated steel housing, powder-coated ‘Pearl White’.
- Designed for in-wall mounting.
- Strong and secure all steel construction.
- Weatherproof inlet grille.
- Powder-coated Centrifugal fan.
- 3-speed facility, connected on-site.
- F5 filter included as standard, see Special Notes
- Bushfire model fitted with stainless steel or bronze mesh.
- Durable zinc coated steel housing, powder-coated ‘Pearl White’.
- Designed for in-wall mounting.
- Strong and secure all steel construction.
- Weatherproof inlet grille.
- Powder-coated Centrifugal fan.
- 3-speed facility, connected on-site.
- F5 filter included as standard, see Special Notes
- Bushfire model fitted with stainless steel or bronze mesh.
Construction
Zinc coated, ‘Pearl White’ powder-coated steel housing.
Integral weatherproof inlet grille providing security.
Filter in fan discharge is standard.
Motor
Type - external rotor, squirrel cage induction motor.
Electricity supply- 230V, single-phase, 50Hz.
Bearings - sealed-for-life, ball.
Supplied with three speed facility, adjusted on site by a
wiring change.
Class B motor, IP20.
Internal Protection
Auto-reset type fitted as standard.
Testing
Air flow tests to ISO 5801:2017
Noise tests to ISO3744: 2010
Performances shown are based on clean filters.
As air flow will be affected by room pressurisation, care should
be taken to ensure adequate air relief is provided.
Special Note
Wiring Diagram
The unit is provided with a wiring strip mounted internally.
Active, Neutral and an Earth are required to be connected to the
strip. On-Off switches are by others.
Wiring access is provided to allow wiring from inside the
building. See online product page for wiring diagram.
Special Features
Wiring Diagram
The unit is provided with a wiring strip mounted internally.
Active, Neutral and an Earth are required to be connected to the
strip. On-Off switches are by others.
Wiring access is provided to allow wiring from inside the
building. See online product page for wiring diagram.
|
Technical Data - FSU144-Q-BFCSetting | Speed [rps] | Avg. dBA @ 3m | kWatts (Input) | Amps | Max.°C | Approx. Weight [kg] |
---|
Lo | 17 | 36 | 0.178 | 0.82 | 45 | 15 | Mid | 24 | 44 | 0.207 | 0.94 | 45 | 15 | Hi | 33 | 52 | 0.3 | 1.3 | 45 | 15 |
Sound DataSetting | Type | 63 | 125 | 250 | 500 | 1K | 2K | 4K | 8K |
---|
Lo | Outlet | 59 | 55 | 56 | 52 | 51 | 51 | 41 | 38 | Mid | Outlet | 67 | 63 | 64 | 60 | 59 | 59 | 49 | 46 | Hi | Outlet | 74 | 70 | 71 | 67 | 66 | 66 | 56 | 53 |
|